White cascade with bypass valve

 TEMPERATURE UNLOADED :  -105*C

TEMPERATURE LOADED :  -94*C at 260W dummyload

Specs :

compressors: Toshiba PH160T2-4L2 on 1st stage + Toshiba PG180X1C on 2nd stage
evap: steeper 42mm diam/41mm tall
XV: Danfoss TS2/captube 0.9 mm
HX: plate HX , 12 plates
condensers: 4.8 Kw, alu-cu, cooled by 2x 254mm/230V fans + desuperheater for 2nd stage 0.75kW , alu-cu, cooled by 170mm/230V fans
refrigerants : R507/R1150
oilseparator : Shine Year automatic
safety : RANCO cut-off, FACH 1.5l expansion tank
case : Laser cutted and powder coated case, 89 x 71 x 51 cm, wheels
others: Bypass valve - Castel handvalve, 2*REFCO panel gauges (discharge pressure), ANACONDA shocks absorber on 1st stage suction line, polished and clear coated pipes, 350mm fan on back wall